Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Oral Implantol ; 50(1): 31-38, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579114

RESUMO

The aim of this study was to evaluate the mechanical behavior of UCLA and Mini-conical abutments for implants with Tri-channel connections regarding torque loss and vertical misfit. Twenty 3-element metal-ceramic fixed partial dentures (FPD) supported by 2 implants were manufactured and divided into 2 groups (n = 10): UCLA (group 1) and Mini-conical Abutments (group 2). The evaluation of torque loss was carried out before and after mechanical cycling, while the vertical fit was evaluated throughout the different stages of manufacturing the prostheses, as well pre- and postcycling (300,000 cycles, 30 N). Statistical analyses of torque loss and vertical misfit were performed using the linear mixed effects model. Both groups showed torque loss after mechanical cycling (P < .05); however, there was no significant percentage differences between them (P = .795). Before cycling, the groups showed a significant difference in terms of vertical misfit values (P < .05); however, this difference was no long observed after cycling (P = .894). Both groups showed torque loss after the cycling test, with no significant difference (P > .05). There was no significant difference in vertical misfit after mechanical cycling; however, in group 1 (UCLA) there was accommodation of the implant-UCLA abutment interface, while group 2 (Mini-conical abutment) did not show changes in the interface with the implant after the test. Both groups behaved similarly regarding the torque loss of the prosthesis retention screws pre- and postmechanical cycling, with greater loss after the test.


Assuntos
Implantes Dentários , Torque , Dente Suporte , Análise do Estresse Dentário , Retenção em Prótese Dentária , Projeto do Implante Dentário-Pivô
2.
Medicina (Kaunas) ; 59(7)2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37512122

RESUMO

Background and Objectives: The insertion of the dental implant in the bone is an essential step in prosthetic rehabilitation. The insertion torque has the potential to distort the prosthetic platform, which can cause future biomechanical problems with the continuous action of occlusal forces. The aim of this study is to evaluate different insertion torques in the deformation of tri-channel platform connections through two- and three-dimensional measurements with micro-CT. Materials and Methods: A total of 164 implants were divided into groups (platform diameter and type): 3.5, 3.75, and 4.3 mm NP (narrow platform), and 4.3 mm RP (regular platform). Each implant-platform group was then divided into four subgroups (n = 10) with different torques: T45 (45 Ncm), T80 (80 Ncm), T120 (120 Ncm), and T150 (150 Ncm). The implant-abutment-screw assemblies were scanned and the images obtained were analyzed. Results: A significant difference was observed for the linear and volume measures between the different platforms (p < 0.01) and the different implant insertion torques (p < 0.01). Qualitative analysis suggested a higher deformation resistance for the 3.75 NP compared to the 3.5 NP, and RP was more resistant compared to the NP. Conclusions: The 0.25 mm increment in the implant platform did not increase the resistance to the applied insertion torques; the 4.3 mm implant was significantly stronger compared to the 3.5 mm implant; and the proposed micro-CT analysis was considered valid for both the 2D and 3D analyses of micro-gaps, qualitatively and quantitatively.


Assuntos
Próteses e Implantes , Humanos , Microtomografia por Raio-X , Torque
3.
Materials (Basel) ; 16(11)2023 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-37297037

RESUMO

The relationship between bacterial infiltration and internal conical Implant-Abutment Interfaces (IAIs) with different conicities still requires investigations that can offer valuable information in the clinical understanding of peri-implant health. The present study aimed to verify the bacterial infiltration of two internal conical connections with an angulation of 11.5° and 16° with the external hexagonal connection as a comparative after thermomechanical cycling using saliva as a contaminant. Test (n = 10) and control (n = 3) groups were set up. Evaluations were made on torque loss, Scanning Electron Microscopy (SEM), and Micro Computerized Tomography (MicroCT) after performing 2 × 106 mechanical cycles (120 N) and 600 thermal cycles (5°-55° C) with 2 mm lateral displacement. The contents of the IAI were collected for microbiological analysis. There was a difference (p < 0.05) in torque loss of the groups tested; groups from the 16° IAI obtained a lower percentage of torque loss. All groups presented contamination and the analysis of the results shows that the microbiological profile of the IAI differs qualitatively from the profile found in the saliva used for contamination. The mechanical loading affects the microbiological profile found in the IAIs (p < 0.05). In conclusion, the IAI environment may favor a microbiological profile different from that of saliva and the thermocycling condition may alter the microbial profile found in the IAI.

4.
Braz Dent J ; 34(1): 61-70, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36888846

RESUMO

The aim of this in situ study was to evaluate color change, surface roughness, gloss, and microhardness in tooth enamel submitted to whitening and remineralizing toothpastes. Fifteen healthy adults (REBEC - RBR-7p87yr) (with unstimulated salivary flow ≥ 1.5 ml for 5 minutes, pH=7) wore two intraoral devices containing four bovine dental fragments (6 x 6 x 2 mm). Participants were randomly assigned and instructed to toothbrush the devices with the tested toothpastes (30 days): CT: conventional; WT: whitening; WTP: whitening with peroxide, and RT: remineralizing toothpaste. A washout period of 7 days was established. Readouts of color, gloss, surface roughness, and microhardness were performed before and after brushing. The results demonstrated no color, gloss, and microhardness differences (p>0.5). The samples brushed with WTP (0.2(0.7) showed higher surface roughness (p=0.0493) than those with WT (-0.5(1.0). The toothpastes did not alter the properties of the dental enamel, except for the roughness. Toothpaste with an abrasive system based on sodium bicarbonate and silica, and that contains sodium carbonate peroxide increased the surface roughness of the enamel.


Assuntos
Clareamento Dental , Cremes Dentais , Bovinos , Animais , Humanos , Esmalte Dentário , Escovação Dentária , Peróxidos/farmacologia
5.
Braz. dent. j ; 34(1): 61-70, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1420571

RESUMO

Abstract The aim of this in situ study was to evaluate color change, surface roughness, gloss, and microhardness in tooth enamel submitted to whitening and remineralizing toothpastes. Fifteen healthy adults (REBEC - RBR-7p87yr) (with unstimulated salivary flow ≥ 1.5 ml for 5 minutes, pH=7) wore two intraoral devices containing four bovine dental fragments (6 x 6 x 2 mm). Participants were randomly assigned and instructed to toothbrush the devices with the tested toothpastes (30 days): CT: conventional; WT: whitening; WTP: whitening with peroxide, and RT: remineralizing toothpaste. A washout period of 7 days was established. Readouts of color, gloss, surface roughness, and microhardness were performed before and after brushing. The results demonstrated no color, gloss, and microhardness differences (p>0.5). The samples brushed with WTP (0.2(0.7) showed higher surface roughness (p=0.0493) than those with WT (-0.5(1.0). The toothpastes did not alter the properties of the dental enamel, except for the roughness. Toothpaste with an abrasive system based on sodium bicarbonate and silica, and that contains sodium carbonate peroxide increased the surface roughness of the enamel.


Resumo O objetivo deste estudo in situ foi avaliar a alteração de cor, rugosidade superficial, brilho e microdureza em esmalte dentário submetido a dentifrícios clareadores e remineralizantes. Quinze adultos saudáveis (REBEC - RBR-7p87yr) (com fluxo salivar não estimulado ≥ 1.5 mL por 5 minutos, pH = 7) usaram dois dispositivos intrabucais contendo quatro fragmentos dentários bovinos (6 x 6 x 2 mm). Os participantes foram aleatoriamente designados e instruídos a escovar os aparelhos com os dentifrícios testados (30 dias): CO: convencional; CL: clareador; CLP: clareador com peróxido e RE: remineralizante. Foi estabelecido um período de washout de 7 dias. Leituras de cor, brilho, rugosidade superficial e microdureza foram realizadas antes e após a escovação. Os resultados não demonstraram diferenças na cor, brilho e microdureza. As amostras escovadas com CLP apresentaram maior rugosidade superficial (p=0,0493) do que aquelas com CL. Os dentifrícios não alteraram as propriedades do esmalte dental, exceto a rugosidade. O dentifrício com sistema abrasivo à base de bicarbonato de sódio e sílica, e que contém peróxido de carbonato de sódio aumentou a rugosidade de superfície do esmalte.

6.
Medicina (Kaunas) ; 59(1)2023 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-36676752

RESUMO

Background and Objectives: There are limited data regarding the behavior of resin matrix ceramics for current CAD-CAM materials. Further studies may be beneficial and can help clinicians planning to use these materials during prosthodontic rehabilitation. The aim of this study was to evaluate and compare the flexural strength and strain distributions, filler content, wear, and reliability of two resin matrix ceramic CAD-CAM materials. Materials and Methods: Two resin matrix ceramics, Ambarino High-Class (AH) and Vita Enamic (VE), were tested for flexural strength (n = 24), wear (n = 10), and reliability (n = 18). Thermogravimetric analysis was used to determine the percentage of filler by weight, and digital image correlation (DIC) was used for strain analysis in flexural strength test. Reliability of each resin matrix ceramic was compared after accelerated lifetime testing of crowns using a two-parameter Weibull distribution. Data of flexural strength, wear, and thermogravimetry were analyzed by independent t-tests with significance level at 5%. Results: The results of DIC analysis were analyzed by a qualitative comparison between the images obtained. The materials tested showed different flexural strength (p < 0.05) and strain distributions. The filler content was the same as informed by manufacturers. No difference was observed in the wear or reliability analysis (p > 0.05). The flexural strength of material AH was superior to VE, and the strain distribution was compatible with this finding. Conclusions: The two resin matrix ceramics tested showed similar behavior in wear and reliability analysis. Both can provide safe use for dental crowns.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Humanos , Teste de Materiais , Reprodutibilidade dos Testes , Cerâmica
7.
Rev. odontol. UNESP (Online) ; 49: e20200047, 2020. tab, ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1156802

RESUMO

Introduction: The cantilever length of implant-supported fixed prosthesis metal structure has been considered an important factor to transfer occlusion forces to the dental implant. Objective: This study evaluated the influence of different extensions of cantilevers of Branemark protocol implant prosthesis when submitted to mechanical thermocycling by screw loosening evaluation. Material and method: The groups G10 (n = 5), G15 (n = 5) and G20 (n = 5) were formed according to the distance in millimeters between the force application site in the cantilever and the center of the last implant. All metal structures (n = 15) were submitted to a 120 N cyclic vertical load in a chewing simulation machine (MSM-Elquip, São Carlos-SP, Brazil) under controlled temperature and moisture conditions. Two hundred and fifty thousand mechanical cycles were performed with a frequency of 2 Hz that simulates a masticatory activity similar to 3 months. To compare the data obtained regarding the loosening of the metal structure screws, implant position and sites of load application, the analysis of variance with two factors and the Tukey test were performed. Result: Statistical analysis showed that the G10 group presented greater torque loss, statistically different from G15 (p = 0.001) and G20 (p = 0.002), and there was no significant difference between groups G15 and G20. Conclusion: It can be concluded from the results that all the screws presented torque loss after simulation of 3 month masticatory activity, suggesting the need for periodical evaluation to prevent failures in the treatment.


Introdução: O comprimento do cantilever da infraestrutura de prótese implanto-suportada tem sido considerado um importante fator de transferência de força de oclusão para o implante dentário. Objetivo: Esse trabalho avaliou a influência das diferentes extensões do cantilever da prótese sobre implantes tipo protocolo de Branemark submetidas à termociclagem mecânica pela avaliação dos afrouxamentos dos parafusos de fixação. Material e método: Os grupos G10 (n=5), G15 (n=5) e G20 (n=5) foram formados de acordo com a distância, em milímetros, entre o local de aplicação de força no cantilever e o centro do último implante. Todas as barras (n=15) foram submetidas a carga vertical cíclica de 120 N em uma máquina de simulação de mastigação (MSM-Elquip, São Carlos/SP, Brasil), em condições de temperatura e umidade controladas. Foram realizados 250 mil ciclos mecânicos com frequência de 2 Hz que simulou uma atividade mastigatória correspondente a 3 meses. Para comparar os dados obtidos quanto à soltura dos parafusos da barra, a posição dos implantes e os locais de aplicação de carga, foi realizada a análise de variância com dois fatores e o teste de Tukey. Resultado: A análise estatística mostrou que o grupo G10 apresentou maior perda de torque, diferente estatisticamente de G15 (p=0,001) e G20 (p=0,002) e que não houve diferença significante entre os grupos G15 e G20. Conclusão: Pode-se concluir que todos os parafusos apresentaram perda de torque após o ensaio simulando uma atividade mastigatória de 3 meses, sugerindo a necessidade de avaliação clínica periódica afim de prevenir fracasso no tratamento.


Assuntos
Próteses e Implantes , Força de Mordida , Implantes Dentários , Torque , Mastigação
8.
RFO UPF ; 24(1): 52-57, 29/03/2019. tab
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1048409

RESUMO

Objective: The present study compared the effectiveness of over-the-counter tooth-whitening strips and too-thbrushing for stain removal. Materials and method: Forty bovine teeth were subjected to initial color re-adings and divided into two groups: 20 teeth were stained with grape juice for seven days and 20 did not receive any treatment (control). Each group was subdivided into two groups (n=10) according to treatment: whitening strips twice/day (30 minutes/7 days) and mechanical brushing with toothpaste (one year). After the treatments, final color readings were taken and color stability (ΔEab), coordinates (ΔL, Δa, Δb), and whitening index (WID) were calculated and analyzed statistically (two-way ANOVA, Bonferroni α=0.05). Results: Statis-tical differences were found for ΔEab and all coordinates between the Control and Stained groups, with major changes in the Stained groups for both treatments. In the Control group, whitening strips produced greater changes in Δb (p <0.05), indicating decrease of yellowness. For the Stained group, whitening strips produced greater changes in Δa (p <0.05), indicating redness reduction. Conclusion: Both treatments were effective for removing stains, and whitening strips were more efficient and effective for changing the color of teeth without previous staining. (AU)


Objetivo: o presente estudo comparou a eficácia das tiras de clareamento dentário e da escovação na remoção de manchas. Materiais e método: quarenta dentes bovinos foram submetidos à lei-tura inicial de cor e divididos em dois grupos: 20 manchados com suco de uva por 7 dias e 20 não receberam tratamento (controle). Cada grupo foi subdividido em 2 grupos (n=10) de acordo com o tratamento: tiras de clareamento 2 vezes/dia (30 minutos/7 dias) e escovação mecânica com cre-me dental (1 ano). Após os tratamentos, leituras finais de cor foram realizadas. Então, a estabili-dade de cor (ΔEab), as coordenadas (ΔL, Δa, Δb) e o índice de clareamento (WID) foram calculados e analisados estatisticamente (two-way ANOVA, Bonferroni α=0,05). Resultados: diferenças es-tatísticas foram encontradas em ΔEab e todas as coordenadas entre os grupos controle e mancha-dos, com maior alteração no grupo manchado, independente do tratamento. No grupo controle, o clareamento produziu maior alteração em Δb (p <0,05), indicando redução do croma amarelo. Nos dentes manchados, ocorreu maior alteração em Δa nos dentes clareados (p <0,05), indicando diminuição do croma vermelho. Conclusão: am-bos os tratamentos foram eficazes na remoção de manchas e o clareamento dentário mostrou-se um método mais eficiente e efetivo para alteração de cor de dentes que não haviam sido submetidos à pigmentação prévia. (AU)


Assuntos
Animais , Bovinos , Clareamento Dental/métodos , Escovação Dentária/métodos , Clareadores Dentários/química , Valores de Referência , Fatores de Tempo , Análise de Variância , Colorimetria , Medicamentos sem Prescrição , Peróxido de Hidrogênio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...